An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches

Matrix converters are devices that allow the management of bidirectional flows of energy with reduced size, increased useful life and high efficiency in ac-ac energy conversion systems. In this paper the experimental results obtained after the application of a predictive current control technique fo...

Szczegółowa specyfikacja

Zapisane w:
Opis bibliograficzny
1. autor: Maqueda Acuña, Edgar Marcial (author)
Kolejni autorzy: Toledo Gallardo, Sergio Ramón (author), Gregor Recalde, Raúl Igmar (author), Caballero Morilla, David Domingo (author), Gavilán Amarilla, Federico José (author), Rodas Benítez, Jorge Esteban (author), Rivera, Marco (author), Wheeler, P. (author)
Format: article
Język:angielski
Wydane: 2017
Hasła przedmiotowe:
Dostęp online:http://hdl.handle.net/20.500.14066/3386
Etykiety: Dodaj etykietę
Nie ma etykietki, Dołącz pierwszą etykiete!
_version_ 1870612063956500480
author Maqueda Acuña, Edgar Marcial
author2 Toledo Gallardo, Sergio Ramón
Gregor Recalde, Raúl Igmar
Caballero Morilla, David Domingo
Gavilán Amarilla, Federico José
Rodas Benítez, Jorge Esteban
Rivera, Marco
Wheeler, P.
author2_role author
author
author
author
author
author
author
author_browse Caballero Morilla, David Domingo
Gavilán Amarilla, Federico José
Gregor Recalde, Raúl Igmar
Maqueda Acuña, Edgar Marcial
Rivera, Marco
Rodas Benítez, Jorge Esteban
Toledo Gallardo, Sergio Ramón
Wheeler, P.
author_facet Maqueda Acuña, Edgar Marcial
Toledo Gallardo, Sergio Ramón
Gregor Recalde, Raúl Igmar
Caballero Morilla, David Domingo
Gavilán Amarilla, Federico José
Rodas Benítez, Jorge Esteban
Rivera, Marco
Wheeler, P.
author_role author
bitstream.checksum.fl_str_mv 7ab386c2e6dd85ba0d3b84fceb07f6f8
858b22fda432bd774e469302988c1974
03c6ec074189f05273843ddca9ed12e7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
bitstream.url.fl_str_mv http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/1/14-INV-097art6.pdf
http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/2/license.txt
http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/3/14-INV-097art6.pdf.txt
dc.contributor.other.es.fl_str_mv Universidad Nacional de Asunción - Facultad de Ingeniería
Universidad de Talca - Faculty of Engineering
University of Nottingham - Dep. of Electrical and Electronic Engineering
dc.creator.none.fl_str_mv Maqueda Acuña, Edgar Marcial
Toledo Gallardo, Sergio Ramón
Gregor Recalde, Raúl Igmar
Caballero Morilla, David Domingo
Gavilán Amarilla, Federico José
Rodas Benítez, Jorge Esteban
Rivera, Marco
Wheeler, P.
dc.date.accessioned.none.fl_str_mv 2022-04-24T17:02:25Z
dc.date.available.none.fl_str_mv 2022-04-24T17:02:25Z
dc.date.issued.none.fl_str_mv 2017
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/20.500.14066/3386
dc.language.iso.es.fl_str_mv eng
dc.relation.projectCONACYT.es.fl_str_mv 14-INV-097
dc.rights.accessRights.es.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.classification.es.fl_str_mv 5. Energía
dc.subject.ocde.es.fl_str_mv INGENIERIA
dc.subject.other.es.fl_str_mv MATRIX CONVERTERS
PREDICTIVE CURRENT CONTROL
SIC-MOSFET
dc.title.es.fl_str_mv An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
dc.type.es.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
description Matrix converters are devices that allow the management of bidirectional flows of energy with reduced size, increased useful life and high efficiency in ac-ac energy conversion systems. In this paper the experimental results obtained after the application of a predictive current control technique for a SiC-MOSFET based direct matrix converter feeding an isolated load are presented. The results obtained are compared with a scheme based on IGBT technology in terms of power consumption and total harmonic distortion.
eu_rights_str_mv openAccess
format article
id CONACYT_016ccd7ccb7ae602bfaa90634802b2f8
language eng
network_acronym_str CONACYT
network_name_str Repositorio Institucional CONACYT
oai_identifier_str oai:repositorio.conacyt.gov.py:20.500.14066/3386
publishDate 2017
publishDateSort 2017
repository.mail.fl_str_mv repositorio.institucional@conacyt.gov.py
repository.name.fl_str_mv Repositorio Institucional CONACYT
repository_id_str
spelling 70360011166005696000000-0002-7717-4100210600499600975600f5a34336-f380-4a8a-9597-f4eaf02dd82f6009136623a-11eb-4630-8f28-e7b4c39c65ce600Universidad Nacional de Asunción - Facultad de IngenieríaUniversidad de Talca - Faculty of EngineeringUniversity of Nottingham - Dep. of Electrical and Electronic Engineering2022-04-24T17:02:25Z2022-04-24T17:02:25Z2017http://hdl.handle.net/20.500.14066/3386Matrix converters are devices that allow the management of bidirectional flows of energy with reduced size, increased useful life and high efficiency in ac-ac energy conversion systems. In this paper the experimental results obtained after the application of a predictive current control technique for a SiC-MOSFET based direct matrix converter feeding an isolated load are presented. The results obtained are compared with a scheme based on IGBT technology in terms of power consumption and total harmonic distortion.Consejo Nacional de Ciencia y TecnologíaPROCIENCIAeng5. EnergíaMATRIX CONVERTERSPREDICTIVE CURRENT CONTROLSIC-MOSFETINGENIERIAAn assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switchesinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion2017Puerto Varas, CL3rd IEEE Southern Power Electronics Conference, SPEC 2017, held in Hotel Enjoy14-INV-097info:eu-repo/semantics/openAccessMaqueda Acuña, Edgar MarcialToledo Gallardo, Sergio RamónGregor Recalde, Raúl IgmarCaballero Morilla, David DomingoGavilán Amarilla, Federico JoséRodas Benítez, Jorge EstebanRivera, MarcoWheeler, P.ORIGINAL14-INV-097art6.pdf14-INV-097art6.pdfapplication/pdf13443764http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/1/14-INV-097art6.pdf7ab386c2e6dd85ba0d3b84fceb07f6f8MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81698http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/2/license.txt858b22fda432bd774e469302988c1974MD52TEXT14-INV-097art6.pdf.txt14-INV-097art6.pdf.txtExtracted texttext/plain22265http://repositorio.conacyt.gov.py/bitstream/20.500.14066/3386/3/14-INV-097art6.pdf.txt03c6ec074189f05273843ddca9ed12e7MD5320.500.14066/3386oai:repositorio.conacyt.gov.py:20.500.14066/33862026-02-12 19:30:27.319Repositorio Institucional CONACYTrepositorio.institucional@conacyt.gov.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
spellingShingle An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
Maqueda Acuña, Edgar Marcial
5. Energía
MATRIX CONVERTERS
PREDICTIVE CURRENT CONTROL
SIC-MOSFET
INGENIERIA
status_str publishedVersion
title An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
title_full An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
title_fullStr An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
title_full_unstemmed An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
title_short An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
title_sort An assessment of predictive current control applied to the direct matrix converter based on SiC-MOSFET bidirectional switches
topic 5. Energía
MATRIX CONVERTERS
PREDICTIVE CURRENT CONTROL
SIC-MOSFET
INGENIERIA
url http://hdl.handle.net/20.500.14066/3386