Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión
Rotating electric machines with operating voltage greater than 12 [kV] are an integral part of the installed base of electric generators in different countries. These voltages incorporate new challenges to be solved in maintenance practices. One of the most important challenges is the identification...
Na minha lista:
| Autor principal: | |
|---|---|
| Outros Autores: | , |
| Formato: | article |
| Idioma: | inglês |
| Publicado em: |
2018
|
| Acesso em linha: | https://knepublishing.com/index.php/KnE-Engineering/article/view/1468 http://ridda2.utp.ac.pa/handle/123456789/4348 |
| Tags: |
Sem tags, seja o primeiro a adicionar uma tag!
|
| _version_ | 1869652458384392192 |
|---|---|
| author | Mata, Oscar Núñez |
| author2 | Vargas, Gerard Rodríguez Oviedo, Rolando Rolando |
| author2_role | author author |
| author_browse | Mata, Oscar Núñez Oviedo, Rolando Rolando Vargas, Gerard Rodríguez |
| author_facet | Mata, Oscar Núñez Vargas, Gerard Rodríguez Oviedo, Rolando Rolando |
| author_role | author |
| collection | Repositorio Institucional de documento digitales de acceso abierto de la UTP |
| dc.contributor.none.fl_str_mv | |
| dc.creator.none.fl_str_mv | Mata, Oscar Núñez Vargas, Gerard Rodríguez Oviedo, Rolando Rolando Mata, Oscar Núñez Vargas, Gerard Rodríguez Oviedo, Rolando Rolando |
| dc.date.none.fl_str_mv | 2018-02-11 2018-02-23T17:16:29Z 2018-02-23T17:16:29Z |
| dc.format.none.fl_str_mv | application/msword application/pdf application/xml |
| dc.identifier.none.fl_str_mv | https://knepublishing.com/index.php/KnE-Engineering/article/view/1468 10.18502/keg.v3i1.1468 http://ridda2.utp.ac.pa/handle/123456789/4348 |
| dc.language.none.fl_str_mv | eng |
| dc.publisher.none.fl_str_mv | KnE Publishing |
| dc.relation.none.fl_str_mv | https://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3278 https://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3539 https://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3540 |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/4.0/ |
| dc.source.none.fl_str_mv | 2518-6841 KnE Engineering; 6th Engineering, Science and Technology Conference - Panama 2017 (ESTEC 2017); 645-656 reponame:Repositorio Institucional de documento digitales de acceso abierto de la UTP instname:Universidad Tecnológica de Panamá instacron:U Tecnológica de Panamá |
| dc.title.none.fl_str_mv | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| description | Rotating electric machines with operating voltage greater than 12 [kV] are an integral part of the installed base of electric generators in different countries. These voltages incorporate new challenges to be solved in maintenance practices. One of the most important challenges is the identification of the condition of the stator winding. For many years, the most commonly used monitoring techniques in electrical generators were off-line insulation measurements, especially in direct current. More recently, the use of on-line insulation monitoring techniques has enabled problems to be detected in advance, such as partial discharge measurement. This article presents the measurement of on-line partial discharges, as a condition monitoring technique for high voltage electric generators. It is also used for risk assessment and decision support for corrective actions. In the case study, it was evidenced that periodic monitoring is key during the operating time of the evaluated generator unit, which can be extended to other generators. The monitoring of on-line partial discharges allowed to know its condition and evolution through the trend in time.Keywords: Partial discharge, electric generator, failure mode, predictive maintenance, void. |
| eu_rights_str_mv | openAccess |
| format | article |
| id | lrtest_279eb9121a37d40a9e8b2a0af9e32fae |
| identifier_str_mv | 10.18502/keg.v3i1.1468 |
| instacron_str | U Tecnológica de Panamá |
| institution | U Tecnológica de Panamá |
| instname_str | Universidad Tecnológica de Panamá |
| language | eng |
| network_acronym_str | lrtest |
| network_name_str | lr |
| oai_identifier_str | oai:ridda2.utp.ac.pa:123456789/4348 |
| publishDate | 2018 |
| publishDateSort | 2018 |
| publisher.none.fl_str_mv | KnE Publishing |
| reponame_str | Repositorio Institucional de documento digitales de acceso abierto de la UTP |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| rights_invalid_str_mv | https://creativecommons.org/licenses/by/4.0/ |
| spelling | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta TensiónMata, Oscar NúñezVargas, Gerard RodríguezOviedo, Rolando RolandoMata, Oscar NúñezVargas, Gerard RodríguezOviedo, Rolando RolandoRotating electric machines with operating voltage greater than 12 [kV] are an integral part of the installed base of electric generators in different countries. These voltages incorporate new challenges to be solved in maintenance practices. One of the most important challenges is the identification of the condition of the stator winding. For many years, the most commonly used monitoring techniques in electrical generators were off-line insulation measurements, especially in direct current. More recently, the use of on-line insulation monitoring techniques has enabled problems to be detected in advance, such as partial discharge measurement. This article presents the measurement of on-line partial discharges, as a condition monitoring technique for high voltage electric generators. It is also used for risk assessment and decision support for corrective actions. In the case study, it was evidenced that periodic monitoring is key during the operating time of the evaluated generator unit, which can be extended to other generators. The monitoring of on-line partial discharges allowed to know its condition and evolution through the trend in time.Keywords: Partial discharge, electric generator, failure mode, predictive maintenance, void.KnE Publishing2018-02-112018-02-23T17:16:29Z2018-02-23T17:16:29Zinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/mswordapplication/pdfapplication/xmlhttps://knepublishing.com/index.php/KnE-Engineering/article/view/146810.18502/keg.v3i1.1468http://ridda2.utp.ac.pa/handle/123456789/43482518-6841KnE Engineering; 6th Engineering, Science and Technology Conference - Panama 2017 (ESTEC 2017); 645-656reponame:Repositorio Institucional de documento digitales de acceso abierto de la UTPinstname:Universidad Tecnológica de Panamáinstacron:U Tecnológica de Panamáenghttps://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3278https://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3539https://knepublishing.com/index.php/KnE-Engineering/article/view/1468/3540info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/oai:ridda2.utp.ac.pa:123456789/43482021-07-06T16:47:39Z |
| spellingShingle | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión Mata, Oscar Núñez |
| status_str | publishedVersion |
| title | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| title_full | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| title_fullStr | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| title_full_unstemmed | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| title_short | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| title_sort | Monitoreo de Descargas Parciales En-línea en Generadores Eléctricos de Alta Tensión |
| url | https://knepublishing.com/index.php/KnE-Engineering/article/view/1468 http://ridda2.utp.ac.pa/handle/123456789/4348 |