Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas
This paper describes the concepts and procedures for the design and implementation of a water turbidity sensor. It is designed with the purpose of offering us water turbidity readings. The sensor is designed according to the standard ISO 7027 "The water quality, determination of turbidity", which...
Furkejuvvon:
| Váldodahkki: | |
|---|---|
| Eará dahkkit: | |
| Materiálatiipa: | article |
| Giella: | eaŋgalasgiella |
| Almmustuhtton: |
2018
|
| Liŋkkat: | https://knepublishing.com/index.php/KnE-Engineering/article/view/1418 http://ridda2.utp.ac.pa/handle/123456789/4319 |
| Fáddágilkorat: |
Eai fáddágilkorat, Lasit vuosttaš fáddágilkora!
|
| _version_ | 1869652472727863296 |
|---|---|
| author | Vargas, Salvador |
| author2 | Calvo, Jossue |
| author2_role | author |
| author_browse | Calvo, Jossue Vargas, Salvador |
| author_facet | Vargas, Salvador Calvo, Jossue |
| author_role | author |
| collection | Repositorio Institucional de documento digitales de acceso abierto de la UTP |
| dc.contributor.none.fl_str_mv | |
| dc.creator.none.fl_str_mv | Vargas, Salvador Calvo, Jossue |
| dc.date.none.fl_str_mv | 2018-02-11 2018-02-23T17:16:21Z 2018-02-23T17:16:21Z |
| dc.format.none.fl_str_mv | application/msword application/pdf application/xml application/msword application/pdf application/xml |
| dc.identifier.none.fl_str_mv | https://knepublishing.com/index.php/KnE-Engineering/article/view/1418 10.18502/keg.v3i1.1418 http://ridda2.utp.ac.pa/handle/123456789/4319 http://ridda2.utp.ac.pa/handle/123456789/4319 |
| dc.language.none.fl_str_mv | eng |
| dc.publisher.none.fl_str_mv | KnE Publishing |
| dc.relation.none.fl_str_mv | https://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3228 https://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3439 https://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3440 |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/4.0/ |
| dc.source.none.fl_str_mv | 2518-6841 KnE Engineering; 6th Engineering, Science and Technology Conference - Panama 2017 (ESTEC 2017); 111-119 reponame:Repositorio Institucional de documento digitales de acceso abierto de la UTP instname:Universidad Tecnológica de Panamá instacron:U Tecnológica de Panamá |
| dc.title.none.fl_str_mv | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| description | This paper describes the concepts and procedures for the design and implementation of a water turbidity sensor. It is designed with the purpose of offering us water turbidity readings. The sensor is designed according to the standard ISO 7027 "The water quality, determination of turbidity", which specifies four methods for the determination of the turbidity of the water. The light source is an infrared led to 850 nm which is modulated in frequency to prevent external light interference, so that the sensor receiver is immune to external sources of light. The calibration of this sensor gets a sensitivity of 0.0014 V/NTU and a non-linear error less than 10%, for a range between 0.1 NTU to 600 NTU.Keywords: Turbidity, Nephelometer, Turbidimeter, Sensor, Calibration Curve |
| eu_rights_str_mv | openAccess |
| format | article |
| id | lrtest_a86f0fc543a0f68e39a224ce75c78cbe |
| identifier_str_mv | 10.18502/keg.v3i1.1418 |
| instacron_str | U Tecnológica de Panamá |
| institution | U Tecnológica de Panamá |
| instname_str | Universidad Tecnológica de Panamá |
| language | eng |
| network_acronym_str | lrtest |
| network_name_str | lr |
| oai_identifier_str | oai:ridda2.utp.ac.pa:123456789/4319 |
| publishDate | 2018 |
| publishDateSort | 2018 |
| publisher.none.fl_str_mv | KnE Publishing |
| reponame_str | Repositorio Institucional de documento digitales de acceso abierto de la UTP |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| rights_invalid_str_mv | https://creativecommons.org/licenses/by/4.0/ |
| spelling | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz ExternasVargas, SalvadorCalvo, JossueThis paper describes the concepts and procedures for the design and implementation of a water turbidity sensor. It is designed with the purpose of offering us water turbidity readings. The sensor is designed according to the standard ISO 7027 "The water quality, determination of turbidity", which specifies four methods for the determination of the turbidity of the water. The light source is an infrared led to 850 nm which is modulated in frequency to prevent external light interference, so that the sensor receiver is immune to external sources of light. The calibration of this sensor gets a sensitivity of 0.0014 V/NTU and a non-linear error less than 10%, for a range between 0.1 NTU to 600 NTU.Keywords: Turbidity, Nephelometer, Turbidimeter, Sensor, Calibration CurveKnE Publishing2018-02-112018-02-23T17:16:21Z2018-02-23T17:16:21Zinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/mswordapplication/pdfapplication/xmlapplication/mswordapplication/pdfapplication/xmlhttps://knepublishing.com/index.php/KnE-Engineering/article/view/141810.18502/keg.v3i1.1418http://ridda2.utp.ac.pa/handle/123456789/4319http://ridda2.utp.ac.pa/handle/123456789/43192518-6841KnE Engineering; 6th Engineering, Science and Technology Conference - Panama 2017 (ESTEC 2017); 111-119reponame:Repositorio Institucional de documento digitales de acceso abierto de la UTPinstname:Universidad Tecnológica de Panamáinstacron:U Tecnológica de Panamáenghttps://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3228https://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3439https://knepublishing.com/index.php/KnE-Engineering/article/view/1418/3440info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/oai:ridda2.utp.ac.pa:123456789/43192021-07-06T16:47:37Z |
| spellingShingle | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas Vargas, Salvador |
| status_str | publishedVersion |
| title | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| title_full | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| title_fullStr | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| title_full_unstemmed | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| title_short | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| title_sort | Sistema Nefelometrico Auto-referenciado Inmune a Fuentes de Luz Externas |
| url | https://knepublishing.com/index.php/KnE-Engineering/article/view/1418 http://ridda2.utp.ac.pa/handle/123456789/4319 |